Discusión y Referencias
|
|
|
|
API RP 1111 Design, Construction, Operation,
and Maintenance of Offshore Hydrocarbon Pipelines (Limit State Design)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Tablas y Estándares
|
|
|
-
|
Tabla D-1 Specified Minimum Yield Strength
for Steel Pipe Commonly Used in Piping Systems
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
-
|
Tabla A842.2.2-1 Design Factors for Offshore
Pipelines, Platform Piping, and Pipeline Risers
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
-
|
Tabla 841.1.8-1 Temperature Derating Factor,
T, for Steel Pipe
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
-
|
ASME B36.10M-Welded and Seamless Wrought
Steel Pipe
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
-
|
ASME B36.19M-Stainless Steel Pipe
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Colapso debido a Presión Externa:
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
La presión de colapso de la tubería debe exceder
la presión externa neta en todas partes a lo largo de la tubería de la
siguiente manera:
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Donde:
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
fo es el factor de
colapso;
|
|
|
|
foPc ≥ (Po-Pi)
|
|
|
|
|
|
|
(9)
|
= 0.7
para tubos sin costura o soldados por resistencia eléctrica (ERW);
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
= 0.6
para tubería expandida en frío, como tubería soldada con doble arco sumergido
(DSAW);
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Pc es la presión de colapso de la tubería, en
N/mm² (psi).
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Las siguientes
ecuaciones se pueden usar para aproximar la presión de colapso:
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Pc =
|
PyPe
|
|
|
|
|
|
|
|
(10)
|
Donde:
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(Py²+Pe²)
|
½
|
|
|
|
|
|
|
E
es el módulo de elasticidad, en N/mm² (psi);
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
v
es la relación de Poisson;
|
|
|
|
|
Py =
|
2S
|
(
|
t
|
)
|
|
|
|
|
|
|
(11)
|
Pe
es la presión de colapso elástico de la tubería,
en N/mm² (psi);
|
|
|
|
|
D
|
|
|
|
|
|
|
Py
es la presión de fluencia en colapso, en N/mm² (psi).
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
La presión de colapso estimada por estas u otras
ecuaciones debe compararse con la presión hidrostática
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
debida a la profundidad del agua para garantizar
que se elija un espesor de pared adecuado para el rango
|
|
|
|
|
|
|
(
|
t
|
)
|
3
|
|
|
|
|
|
(12)
|
de profundidades del agua que se va a encontrar.
|
|
|
|
|
Pe =
|
2E
|
D
|
|
|
|
|
|
|
|
|
|
|
|
(1-v²)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Pandeo debido a la
flexión y presión externa combinadas
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
La deformación por
flexión y cargas por presión externa combinadas deben satisfacer lo
siguiente:
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ε
|
+
|
(Po-Pi)
|
≤ g(δ)
|
|
|
(13)
|
Donde:
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
εb
|
fcPc
|
|
|
fc es el factor de colapso
para uso con cargas combinadas de presión y flexión;
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
valor recomendado para fc =
|
|
fo
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ε =
|
{
|
g(δ) -
|
(Po-Pi)
|
}
|
x εb
|
|
|
|
g(δ)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(fcPc)
|
|
|
Para las condiciones
de instalación, se puede considerar factores de colapso más altos hasta 1.0.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Independientemente
de la selección del valor de fc, las condiciones para el colapso en la ecuación (9)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
deben cumplirse.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
g(δ) factor de reducción del colapso =
|
(1+20δ)ˉ¹
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
δ Ovalidad =
|
|
Dmax
- Dmin
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Dmax
+ Dmin
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Dmax es el diámetro máximo en cualquier sección transversal dada,
en mm (in.);
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Dmin es el diámetro mínimo en cualquier sección transversal dada,
en mm (in.).
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
εb deformación por pandeo bajo flexión pura =
|
|
t
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2D
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ε
es la deformación por flexión permisible en la
tubería [en presencia de presión externa];
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NOTA: La ecuación (13) es
aceptable para un D/t máximo = 50
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Para evitar pandeo, la
deformación por flexión debe ser limitada como
sigue:
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ε ≥ f₁ε₁
|
|
|
|
|
|
|
|
|
(14)
|
ε1 es la deformación máxima por
flexión en la instalación;
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ε2 es la deformación máxima por
flexión in situ;
|
|
|
|
ε ≥ f₂ε₂
|
|
|
|
|
|
|
|
|
(15)
|
f1 es el factor de seguridad de
flexión por flexión en la instalación más presión externa;
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
f2 es el factor de seguridad de
flexión por flexión in situ más presión externa;
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
f₁, factor de seguridad de flexión por flexión de instalación más
presión externa:
|
|
|
|
El factor de seguridad de 3.33 para la instalación
permite un gran aumento en la deformación por flexión antes de que se alcance
la tensión de flexión por
|
|
|
|
pandeo crítica. Este factor de seguridad debe
seleccionarse en función de la estabilidad posicional de la gabarra durante
la colocación dinámica del tendido y
|
|
|
|
el grado subjetivo de riesgo que se tolerará. Los
factores de seguridad más bajos pueden estar justificados para condiciones
excepcionales; por ejemplo,
|
|
|
|
límites del equipo de tendido, restricciones
económicas u otros factores. (f1 = 3.33)
|
|
|
|
ε₁, deformación máxima por flexión en la instalación;
|
|
|
|
La deformación
máxima por flexión en la instalación se determina típicamente por análisis de
la instalación, limitaciones del equipo del contratista y
|
|
|
|
especificaciones del propietario de la tubería. El
valor seleccionado de 0.15% se ha utilizado en numerosos proyectos de
tuberías. (ε1 = 0.0015)
|
|
|
|
f₂, factor de seguridad de flexión por flexión in situ más
presión externa:
|
|
|
|
El factor de seguridad de 2.0 para la operación
permite un aumento significativo de la deformación por flexión antes de que
se alcance la tensión de flexión
|
|
|
|
por pandeo crítica. Este factor de seguridad se
reduce en comparación con el factor de seguridad de la instalación, ya que
las deformaciones por flexión
|
|
|
|
máximas esperadas se pueden definir con mayor
precisión debido a las condiciones de contorno conocidas. En muchos casos, se
puede demostrar que las
|
|
|
|
deformaciones de flexión en operación o in situ
son auto limitantes debido a la geometría de soporte. (f2 = 2.0)
|
|
|
|
ε₂, deformación máxima por flexión
in situ;
|
|
|
|
El análisis de tuberías estructurales in situ y
las especificaciones del propietario de la tubería generalmente determinan la
deformación máxima de flexión en
|
|
|
|
operación. El valor seleccionado de 0.15% es
típico para proyectos de tendidos de tuberías. (ε2 = 0.0015)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|